由于無分電器點火系統(tǒng)有兩個或多個點火線圈或點火線圈初級繞組,所以點火控制器一般除了具有自動斷電功能、導(dǎo)通角控制、恒流控制等電路外,還有氣缸判別電路和多個大功率三極管及相應(yīng)的控制電路
Since the distributor less ignition system has two or more ignition coils or primary windings of ignition coils, the ignition controller generally has not only automatic power-off function, conduction angle control, constant current control and other circuits, but also cylinder discrimination circuit, multiple high-power triodes and corresponding control circuits
點火模塊又稱點火控制器,通過環(huán)境不同的要求,可選擇金屬探棒或紫外光敏管的配合使用,能夠?qū)崿F(xiàn)對自動點火,火焰指示,熄火報警,信號傳送工作自動。點火模塊具有體積小,重量輕,點火強(qiáng),反應(yīng)靈敏等特點,可廣泛用于各種工業(yè)對氣體或液體所產(chǎn)生的火焰進(jìn)行監(jiān)測,熄火保護(hù)。
Ignition module, also known as ignition controller, can be used with metal probe or UV photosensitive tube according to different environmental requirements, which can realize automatic ignition, flame indication, flameout alarm and signal transmission. The ignition module has the characteristics of small volume, light weight, strong ignition and sensitive response. It can be widely used in various industries to monitor and extinguish the flame generated by gas or liquid.
點火模塊通電后電源指示燈亮(綠燈),開關(guān)在ON/OFF狀態(tài)下無上電反應(yīng),開啟開關(guān)-ON-系統(tǒng)自檢點火0.6秒后開啟電磁閥,檢測到有火焰信號,停止點火,工作指示燈亮(黃燈)。不著火點火時間為10秒,任意時間內(nèi)熄火均可重點火,重點火期間檢測到有火焰信號則進(jìn)入正常工作狀態(tài),10秒內(nèi)無火焰信號則關(guān)閉電磁閥報警指示燈亮(紅色)。使用遠(yuǎn)傳控制功能,需外接24VDC電源輸入,通過開關(guān)的閉合實現(xiàn)對控制器進(jìn)行開啟,關(guān)閉控制。在汽車行業(yè)點火模塊和混合集成電路(HIC)、點火開關(guān)、點火線圈、點火分電器組成點火系統(tǒng)。
After the ignition module is powered on, the power indicator light is on (green light), and the switch has no power on response in the on / off state. Turn on the switch - on - the system self checks the ignition, turn on the solenoid valve after 0.6 seconds, detect a flame signal, stop the ignition, and the work indicator light is on (yellow light). The ignition time without fire is 10 seconds. The key fire can be stopped at any time. If a flame signal is detected during the key fire, it will enter the normal working state. If there is no flame signal within 10 seconds, the solenoid valve will be closed and the alarm indicator light will be on (red). The remote control function requires external 24VDC power input, and the controller can be opened and closed by closing the switch. In the automotive industry, the ignition module, hybrid integrated circuit (HIC), ignition switch, ignition coil and ignition distributor constitute the ignition system.